Datasheet Texas Instruments LMK61E2-SIAT — Datenblatt
Hersteller | Texas Instruments |
Serie | LMK61E2 |
Artikelnummer | LMK61E2-SIAT |
Voll programmierbarer Oszillator mit extrem geringem Jitter, integriertem EEPROM, +/- 50 ppm 8-QFM -40 bis 85
Datenblätter
LMK61E2 Ultra-Low Jitter Programmable Oscillator With Internal EEPROM datasheet
PDF, 1.4 Mb, Revision: B, Datei veröffentlicht: Feb 3, 2017
Auszug aus dem Dokument
Preise
Status
Lifecycle Status | Active (Recommended for new designs) |
Manufacture's Sample Availability | Yes |
Verpackung
Pin | 8 |
Package Type | SIA |
Industry STD Term | QFM |
JEDEC Code | R-PSIP-N |
Package QTY | 250 |
Carrier | SMALL T&R |
Device Marking | LMK61E2 |
Width (mm) | 5 |
Length (mm) | 7 |
Thickness (mm) | .8 |
Pitch (mm) | 1.85 |
Max Height (mm) | 1.15 |
Mechanical Data | Herunterladen |
Parameter
Additional Features | 7x5mm |
Jitter | 0.1 ps |
Operating Temperature Range | -40 to 85 C |
Output Frequency(Max) | 1000 MHz |
Output Level | HCSL,LVDS,LVPECL |
Pin/Package | 8QFM |
Rating | Catalog |
Special Features | Programmable with EEPROM |
Stability | 50 ppm |
VCC Core | 3.3 V |
Öko-Plan
RoHS | Compliant |
Design Kits und Evaluierungsmodule
- Evaluation Modules & Boards: LMK61E2EVM
LMK61E2EVM Ultra-Low-Jitter Programmable Oscillator Evaluation Module
Lifecycle Status: Active (Recommended for new designs)
Anwendungshinweise
- Time Domain Jitter Measurement Consideration for Low-Noise OscillatorsPDF, 321 Kb, Datei veröffentlicht: Oct 5, 2015
Phase Noise and Jitter are important metrics that describe the quality of a low-noise oscillator. Jitter is a time-domain representation of the timing accuracy of a signal and Phase Noise is the frequency domain representation of noise spectrum around the carrier tone. Equipment for measuring jitter in time-domain, such as real-time oscilloscopes, excel in their ability to directly measure period - Clocking for Medical Ultrasound SystemsPDF, 1.8 Mb, Datei veröffentlicht: Sep 20, 2017
- Frequency Margining Using TI's High Performance Programmable OscillatorsPDF, 871 Kb, Datei veröffentlicht: Oct 2, 2015
Crystal oscillators and/or multiple output clock generators are critical in today’s high performance consumer, computing, and communications systems. Deciding an optimal clock rate for the system can sometimes require several rounds of prototyping and validation. Clock Generators and Oscillator ICs - with the right hooks to margin synthesized clocks - can help to streamline the overall product dev - Vibration and Shock Sensitivity: A Comparative Study of OscillatorsPDF, 2.8 Mb, Datei veröffentlicht: Jan 11, 2017
When designing a system that incorporates a clock oscillator, the vibration sensitivity of the oscillatordevice is a specification that is easily overlooked. Sensitivity to vibration can have a detrimental impact onthe overall system performance. Since crystal oscillators fundamentally rely on the vibration andmechanical resonance of a piezoelectric material, external disturbances can couple
Modellreihe
Serie: LMK61E2 (6)
Herstellerklassifikation
- Semiconductors > Clock and Timing > Clock Oscillators
Andere Namen:
LMK61E2SIAT, LMK61E2 SIAT