Datasheet Texas Instruments BQ26220PW — Datenblatt
Hersteller | Texas Instruments |
Serie | BQ26220 |
Artikelnummer | BQ26220PW |
FLASH-basierter Präzisions-Multi-Chemie-Lade- / Entladezähler mit Spannungsmessung und HDQ Comm 8-TSSOP -20 bis 70
Datenblätter
High-Performance Battery Monitor IC with Coulomb Counter datasheet
PDF, 1.1 Mb, Revision: B, Datei veröffentlicht: Jan 30, 2004
Auszug aus dem Dokument
Preise
Status
Lifecycle Status | NRND (Not recommended for new designs) |
Manufacture's Sample Availability | No |
Verpackung
Pin | 8 |
Package Type | PW |
Industry STD Term | TSSOP |
JEDEC Code | R-PDSO-G |
Package QTY | 100 |
Carrier | TUBE |
Device Marking | 26220 |
Width (mm) | 4.4 |
Length (mm) | 3 |
Thickness (mm) | 1 |
Pitch (mm) | .65 |
Max Height (mm) | 1.2 |
Mechanical Data | Herunterladen |
Ersatz
Replacement | BQ27010DRKR |
Replacement Code | F |
Öko-Plan
RoHS | Compliant |
Anwendungshinweise
- Choosing Between Battery Gas Gauges & Monitors to Track Charge AvailabililityPDF, 184 Kb, Datei veröffentlicht: Sep 27, 2005
Some customers are unfamiliar with battery monitors or gas gauges for their handheld portable applications. The intent of this application report is to provide information about TI product families that are excellent options when selecting a battery gas gauge solution. - HDQ Compatibility Between OMAP and BQ ProductsPDF, 76 Kb, Datei veröffentlicht: Jun 17, 2004
TI OMAP? and battery management products are found in today's fast-paced developing market of handheld products that include cellular phones with integrated camera and video recorder features, PDAs with wireless capabilities, and advanced handheld gaming systems. In many of these systems, both OMAP and battery management products coexist. OMAP platforms have an HDQ engine that is used to communica - Gas Gauging Basics Using TI Battery Monitor ICs (Rev. A)PDF, 252 Kb, Revision: A, Datei veröffentlicht: Oct 17, 2003
To solve the challenges of precise capacity tracking and monitoring, Texas Instruments has developed a family of accurate battery monitor devices. These devices use the coulomb counting method in order to provide the user with accurate and reliable information about the battery?s state of charge. The purpose of this report is to provide the basics of building an accurate gas-gauging feature using - HDQ Communication Basics (Rev. A)PDF, 103 Kb, Revision: A, Datei veröffentlicht: Sep 18, 2008
This report compares the communication timing specifications for the different battery gas gauge and battery monitor products. It discusses some of the interface requirements necessary for robust HDQ communication, such as the need for a break prior to each communication, how to reliably read 16-bit dynamic values over the 8-bit bus, and the need for some noise filtering on the HDQ line. It also
Modellreihe
Serie: BQ26220 (4)
- BQ26220PW BQ26220PWG4 BQ26220PWR BQ26220PWRG4
Herstellerklassifikation
- Semiconductors > Power Management > Battery Management Products > Battery Fuel Gauge