Datasheet Texas Instruments BQ26200PWR — Datenblatt

HerstellerTexas Instruments
SerieBQ26200
ArtikelnummerBQ26200PWR
Datasheet Texas Instruments BQ26200PWR

FLASH-basierter Präzisions-Multi-Chemie-Lade- / Entladezähler mit 1-Draht-I / F (HDQ) 8-TSSOP 0 bis 70

Datenblätter

High-Performance Battery Coulomb Counter for Cellular Phone Applications datasheet
PDF, 1.1 Mb, Revision: A, Datei veröffentlicht: Nov 3, 2004
Auszug aus dem Dokument

Preise

Status

Lifecycle StatusNRND (Not recommended for new designs)
Manufacture's Sample AvailabilityNo

Verpackung

Pin8
Package TypePW
Industry STD TermTSSOP
JEDEC CodeR-PDSO-G
Package QTY2000
CarrierLARGE T&R
Device Marking26200
Width (mm)4.4
Length (mm)3
Thickness (mm)1
Pitch (mm).65
Max Height (mm)1.2
Mechanical DataHerunterladen

Öko-Plan

RoHSCompliant

Design Kits und Evaluierungsmodule

  • Evaluation Modules & Boards: BQ26200EVM-001
    BQ26200 Battery Monitor Evaluation Module
    Lifecycle Status: Active (Recommended for new designs)

Anwendungshinweise

  • HDQ Compatibility Between OMAP and BQ Products
    PDF, 76 Kb, Datei veröffentlicht: Jun 17, 2004
    TI OMAP? and battery management products are found in today's fast-paced developing market of handheld products that include cellular phones with integrated camera and video recorder features, PDAs with wireless capabilities, and advanced handheld gaming systems. In many of these systems, both OMAP and battery management products coexist. OMAP platforms have an HDQ engine that is used to communica
  • Gas Gauging Basics Using TI Battery Monitor ICs (Rev. A)
    PDF, 252 Kb, Revision: A, Datei veröffentlicht: Oct 17, 2003
    To solve the challenges of precise capacity tracking and monitoring, Texas Instruments has developed a family of accurate battery monitor devices. These devices use the coulomb counting method in order to provide the user with accurate and reliable information about the battery?s state of charge. The purpose of this report is to provide the basics of building an accurate gas-gauging feature using
  • HDQ Communication Basics (Rev. A)
    PDF, 103 Kb, Revision: A, Datei veröffentlicht: Sep 18, 2008
    This report compares the communication timing specifications for the different battery gas gauge and battery monitor products. It discusses some of the interface requirements necessary for robust HDQ communication, such as the need for a break prior to each communication, how to reliably read 16-bit dynamic values over the 8-bit bus, and the need for some noise filtering on the HDQ line. It also

Modellreihe

Herstellerklassifikation

  • Semiconductors > Power Management > Battery Management Products > Battery Fuel Gauge