Datasheet Texas Instruments ADS1192 — Datenblatt
Hersteller | Texas Instruments |
Serie | ADS1192 |
Komplettes integriertes analoges Frontend mit geringem Stromverbrauch für EKG-Anwendungen
Datenblätter
Low-Power, 2-Channel, 16-Bit Analog Front-End for Biopotential Measurements datasheet
PDF, 2.0 Mb, Revision: A, Datei veröffentlicht: Sep 4, 2012
Auszug aus dem Dokument
Preise
Status
ADS1192IPBS | ADS1192IPBSR | ADS1192IRSMR | ADS1192IRSMT | |
---|---|---|---|---|
Lifecycle Status | Active (Recommended for new designs) | Active (Recommended for new designs) | Active (Recommended for new designs) | Active (Recommended for new designs) |
Manufacture's Sample Availability | No | Yes | Yes | No |
Verpackung
ADS1192IPBS | ADS1192IPBSR | ADS1192IRSMR | ADS1192IRSMT | |
---|---|---|---|---|
N | 1 | 2 | 3 | 4 |
Pin | 32 | 32 | 32 | 32 |
Package Type | PBS | PBS | RSM | RSM |
Industry STD Term | TQFP | TQFP | VQFN | VQFN |
JEDEC Code | S-PQFP-G | S-PQFP-G | S-PQFP-N | S-PQFP-N |
Package QTY | 250 | 1000 | 3000 | 250 |
Carrier | TUBE | LARGE T&R | LARGE T&R | SMALL T&R |
Device Marking | ADS1192 | ADS1192 | ADS | ADS |
Width (mm) | 5 | 5 | 4 | 4 |
Length (mm) | 5 | 5 | 4 | 4 |
Thickness (mm) | 1 | 1 | .9 | .9 |
Pitch (mm) | .5 | .5 | .4 | .4 |
Max Height (mm) | 1.2 | 1.2 | 1 | 1 |
Mechanical Data | Herunterladen | Herunterladen | Herunterladen | Herunterladen |
Parameter
Parameters / Models | ADS1192IPBS | ADS1192IPBSR | ADS1192IRSMR | ADS1192IRSMT |
---|---|---|---|---|
# Input Channels | 2 | 2 | 2 | 2 |
Analog Voltage AVDD(Max), V | 5.25 | 5.25 | 5.25 | 5.25 |
Analog Voltage AVDD(Min), V | 2.7 | 2.7 | 2.7 | 2.7 |
Architecture | Delta-Sigma | Delta-Sigma | Delta-Sigma | Delta-Sigma |
Digital Supply(Max), V | 3.6 | 3.6 | 3.6 | 3.6 |
Digital Supply(Min), V | 1.7 | 1.7 | 1.7 | 1.7 |
INL(Max), +/-LSB | 1 | 1 | 1 | 1 |
Input Range(Max), V | 5.25 | 5.25 | 5.25 | 5.25 |
Input Type | Differential,Single-Ended | Differential,Single-Ended | Differential,Single-Ended | Differential,Single-Ended |
Integrated Features | Daisy-Chainable,GPIO,Oscillator,PGA | Daisy-Chainable,GPIO,Oscillator,PGA | Daisy-Chainable,GPIO,Oscillator,PGA | Daisy-Chainable,GPIO,Oscillator,PGA |
Interface | SPI | SPI | SPI | SPI |
Multi-Channel Configuration | N/A | N/A | N/A | N/A |
Operating Temperature Range, C | -40 to 85 | -40 to 85 | -40 to 85 | -40 to 85 |
Package Group | TQFP | TQFP | VQFN | VQFN |
Package Size: mm2:W x L, PKG | 32TQFP: 49 mm2: 7 x 7(TQFP) | 32TQFP: 49 mm2: 7 x 7(TQFP) | 32VQFN: 16 mm2: 4 x 4(VQFN) | 32VQFN: 16 mm2: 4 x 4(VQFN) |
Power Consumption(Typ), mW | 0.67 | 0.67 | 0.67 | 0.67 |
Rating | Catalog | Catalog | Catalog | Catalog |
Reference Mode | Int,Ext | Int,Ext | Int,Ext | Int,Ext |
Resolution, Bits | 16 | 16 | 16 | 16 |
SNR, dB | 92 | 92 | 92 | 92 |
Sample Rate (max), SPS | 8KSPS | 8KSPS | 8KSPS | 8KSPS |
Sample Rate(Max), MSPS | 0.008 | 0.008 | 0.008 | 0.008 |
THD(Typ), dB | -100 | -100 | -100 | -100 |
Öko-Plan
ADS1192IPBS | ADS1192IPBSR | ADS1192IRSMR | ADS1192IRSMT | |
---|---|---|---|---|
RoHS | Compliant | Compliant | Compliant | Compliant |
Anwendungshinweise
- Respiration Rate Measurement Using Impedance PneumographyPDF, 697 Kb, Datei veröffentlicht: Mar 1, 2011
This document discusses the use of impedance pneumography as a technique to measure respiration rate. The generation of high-frequency ac current source is described, and the issues related to delay in modulated signal and finite transition times of carriers are addressed. The report also includesdescriptions of potential implementations of a respiration rate measurement system using the ADS1298 - Understanding Lead-Off Detection in ECG (Rev. A)PDF, 313 Kb, Revision: A, Datei veröffentlicht: Jan 14, 2015
- Improving Common-Mode Rejection Using the Right-Leg Drive AmplifierPDF, 297 Kb, Datei veröffentlicht: Jul 6, 2011
This article discusses the need to improve common-mode rejection (CMR) in electrocardiogram (ECG) subsystem applications. Several different techniques to improve CMR while also considering both patient and operator safety are presented. This report also reviews the implementation of the right-leg drive (RLD) loop technique to improve CMR using the ADS129x family of analog-to-digital converters (in - Analog Front-End Design for ECG Systems Using Delta-Sigma ADCs (Rev. A)PDF, 191 Kb, Revision: A, Datei veröffentlicht: Apr 13, 2010
This document discusses the characteristics of electrocardiogram (ECG) signals and different front-endapproaches for ECG signal acquisition. The tradeoffs between different approaches and the effects on overall system design are discussed. The report also includes descriptions of potential implementations of the front-end architecture using the ADS1258 and ADS1278 and respective noise measuremen - Analog-to-Digital Converter Grounding Practices Affect System Performance (Rev. A)PDF, 69 Kb, Revision: A, Datei veröffentlicht: May 18, 2015
- A Glossary of Analog-to-Digital Specifications and Performance Characteristics (Rev. B)PDF, 425 Kb, Revision: B, Datei veröffentlicht: Oct 9, 2011
This glossary is a collection of the definitions of Texas Instruments' Delta-Sigma (О”ОЈ), successive approximation register (SAR), and pipeline analog-to-digital (A/D) converter specifications and performance characteristics. Although there is a considerable amount of detail in this document, the product data sheet for a particular product specification is the best and final reference. - Principles of Data Acquisition and Conversion (Rev. A)PDF, 132 Kb, Revision: A, Datei veröffentlicht: Apr 16, 2015
Modellreihe
Serie: ADS1192 (4)
Herstellerklassifikation
- Semiconductors> Data Converters> Analog-to-Digital Converters (ADCs)> Precision ADCs (<=10MSPS)