Datasheet Texas Instruments LPV801DBVR — Datenblatt

HerstellerTexas Instruments
SerieLPV801
ArtikelnummerLPV801DBVR
Datasheet Texas Instruments LPV801DBVR

Einkanaliger 450nA Nanopower Operationsverstärker 5-SOT-23 -40 bis 125

Datenblätter

LPV801/LPV802 320 nA Nanopower Operational Amplifiers datasheet
PDF, 1.3 Mb, Revision: B, Datei veröffentlicht: Nov 16, 2016
Auszug aus dem Dokument

Preise

Status

Lifecycle StatusActive (Recommended for new designs)
Manufacture's Sample AvailabilityYes

Verpackung

Pin5
Package TypeDBV
Industry STD TermSOT-23
JEDEC CodeR-PDSO-G
Package QTY3000
CarrierLARGE T&R
Device Marking15VM
Width (mm)1.6
Length (mm)2.9
Thickness (mm)1.2
Pitch (mm).95
Max Height (mm)1.45
Mechanical DataHerunterladen

Parameter

Additional FeaturesEMI Hardened
ArchitectureCMOS
CMRR(Min)80 dB
CMRR(Typ)98 dB
GBW(Typ)0.008 MHz
Iq per channel(Max)0.00054 mA
Iq per channel(Typ)0.00045 mA
Number of Channels1
Offset Drift(Typ)1.5 uV/C
Operating Temperature Range-40 to 125 C
Output Current(Typ)4.7 mA
Package GroupSOT-23
Package Size: mm2:W x L5SOT-23: 8 mm2: 2.8 x 2.9(SOT-23) PKG
Rail-to-RailIn to V-,Out
RatingCatalog
Slew Rate(Typ)0.0018 V/us
Total Supply Voltage(Max)5.5 +5V=5, +/-5V=10
Total Supply Voltage(Min)1.6 +5V=5, +/-5V=10
Vn at 1kHz(Typ)420 nV/rtHz
Vos (Offset Voltage @ 25C)(Max)3.5 mV

Öko-Plan

RoHSCompliant

Design Kits und Evaluierungsmodule

  • Evaluation Modules & Boards: DIP-ADAPTER-EVM
    DIP Adapter Evaluation Module
    Lifecycle Status: Active (Recommended for new designs)

Anwendungshinweise

  • LPV801 Micropower Ionization Smoke Detector
    PDF, 127 Kb, Datei veröffentlicht: Nov 29, 2016
    Ionizationdetectors,as usedin smokealarms,outputa very low currentthat requiresa bufferamplifiertointerfaceto the alarmcircuitry.Thisrequiresa bufferamplifierwith low inputbiascurrent,and,sinceasmokedetectoris a always-on device,the amplifiermustalsohavea verylow quiescentcurrenttomaximizethe batterylife. Thisapplicati
  • Comparing EMI Performance of LPV802 with Other Devices in a Gas Sensor App
    PDF, 4.0 Mb, Datei veröffentlicht: Oct 18, 2016
    Passing the IEC61000-4-3 Radiated EMI test is a requirement for preparing a product for many industrial,medical and consumer markets. This application note presents the results of a simple comparison of theLPV802 nanopower operational amplifier and two other competing devices in a Carbon Monoxide gassensor circuit while subjected to IEC61000-4-3 EMC test conditions.
  • Extend Battery Life and Simplify Calibration in Gas Sensing Applications
    PDF, 140 Kb, Datei veröffentlicht: Sep 22, 2017
  • Precision Voltage Offset: When Does it Matter? (Rev. A)
    PDF, 271 Kb, Revision: A, Datei veröffentlicht: Nov 2, 2016

Modellreihe

Serie: LPV801 (3)

Herstellerklassifikation

  • Semiconductors > Amplifiers > Operational Amplifiers (Op Amps) > Ultra-Low-Power Op Amps (<=10uA)