Datasheet Texas Instruments LM10CWM — Datenblatt
Hersteller | Texas Instruments |
Serie | LM10 |
Artikelnummer | LM10CWM |
Operationsverstärker und Spannungsreferenz 14-SOIC 0 bis 70
Datenblätter
Datasheet LM10
PDF, 3.2 Mb, Revision: E, Datei veröffentlicht: Oct 30, 2015, Seiten: 37
Operational Amplifier and Voltage Reference
Operational Amplifier and Voltage Reference
Auszug aus dem Dokument
Preise
Status
Lifecycle Status | NRND (Not recommended for new designs) |
Manufacture's Sample Availability | No |
Verpackung
Pin | 14 |
Package Type | NPA |
Industry STD Term | SOIC |
JEDEC Code | R-PDSO-G |
Package QTY | 50 |
Carrier | TUBE |
Device Marking | LM10CWM |
Width (mm) | 7.498 |
Length (mm) | 8.992 |
Thickness (mm) | 2.301 |
Pitch (mm) | 1.27 |
Max Height (mm) | 2.65 |
Mechanical Data | Herunterladen |
Ersatz
Replacement | LM10CWM/NOPB |
Replacement Code | S |
Parameter
Additional Features | N/A |
Architecture | Bipolar |
CMRR(Min) | 90 dB |
CMRR(Typ) | 102 dB |
GBW(Typ) | 0.05 MHz |
Input Bias Current(Max) | 20000 pA |
Iq per channel(Max) | 0.4 mA |
Iq per channel(Typ) | 0.27 mA |
Number of Channels | 1 |
Offset Drift(Typ) | 2 uV/C |
Operating Temperature Range | 0 to 70 C |
Output Current(Typ) | 20 mA |
Package Group | SOIC |
Package Size: mm2:W x L | 14SOIC: 93 mm2: 10.325 x 8.9915(SOIC) PKG |
Rail-to-Rail | In to V-,Out |
Rating | Catalog |
Slew Rate(Typ) | 0.2 V/us |
Total Supply Voltage(Max) | 45 +5V=5, +/-5V=10 |
Total Supply Voltage(Min) | 1.1 +5V=5, +/-5V=10 |
Vn at 1kHz(Typ) | 50 nV/rtHz |
Vos (Offset Voltage @ 25C)(Max) | 2 mV |
Öko-Plan
RoHS | See ti.com |
Anwendungshinweise
- AN-211 New Op Amp Ideas (Rev. A)PDF, 1.4 Mb, Revision: A, Datei veröffentlicht: May 6, 2013
An op amp and voltage reference capable of single supply operation down to 1.1V is introduced.Performance is uncompromised and compares favorably with standard, state-of-the-art devices. In adeparture from conventional approaches, the circuit can operate in a floating mode, powered by residualvoltages, independent of fixed supplies. A brief description of the IC design is given, but emphasis - AN-300 Simple Circuit Detects Loss of 4-20 mA Signal (Rev. B)PDF, 241 Kb, Revision: B, Datei veröffentlicht: Apr 23, 2013
Four-to-twenty milliampere current loops are commonly used in the process control industry. They takeadvantage of the fact that a remote amplifier can be powered by the same 4-20 mA current that it controlsas its output signal, thus using a single pair of wires for signal and power. Circuits for making 4-20 mAtransmitters are found in the LM10, LM163, and LH0045 data sheets. - AN-288 System-Oriented DC-DC Conversion Techniques (Rev. B)PDF, 833 Kb, Revision: B, Datei veröffentlicht: May 6, 2013
This application note discusses the operation of system-oriented DC-DC conversion techniques. - Applying a New Precision Op AmpPDF, 421 Kb, Datei veröffentlicht: Oct 4, 2004
- Using ADC0808/809 8-Bit uP Compble ADCs w/8-Chan Analog Multiplexr (Rev. B)PDF, 1.4 Mb, Revision: B, Datei veröffentlicht: Apr 22, 2013
This application note discusses the use of the ADC0808/ADC0809 Data Acquisition Devices (DAD) withan 8-channel analog multiplexer. - Audio Applications of Linear Integrated CircuitsPDF, 272 Kb, Datei veröffentlicht: May 2, 2004
- AN-298 Isolation Techniques for Signal Conditioning (Rev. B)PDF, 685 Kb, Revision: B, Datei veröffentlicht: May 6, 2013
This application note provides information and examples of isolation techniques for signal conditioning. - Effect of Heavy Loads on Accuracy and Linearity of Op Amp Circuits (Rev. B)PDF, 81.7 Mb, Revision: B, Datei veröffentlicht: Apr 22, 2013
This application report discusses the effect of heavy loads on the accuracy and linearity of operationalamplifier circuits.
Modellreihe
Serie: LM10 (5)
Herstellerklassifikation
- Semiconductors > Amplifiers > Operational Amplifiers (Op Amps) > General-Purpose Op Amps