Datasheet Texas Instruments UC2854DW — Datenblatt

HerstellerTexas Instruments
SerieUC2854
ArtikelnummerUC2854DW
Datasheet Texas Instruments UC2854DW

High Power Factor Preregulator 16-SOIC -40 bis 85

Datenblätter

UCx854 High-Power Factor Preregulator datasheet
PDF, 949 Kb, Revision: A, Datei veröffentlicht: Dec 16, 2016
Auszug aus dem Dokument

Preise

Status

Lifecycle StatusActive (Recommended for new designs)
Manufacture's Sample AvailabilityYes

Verpackung

Pin16
Package TypeDW
Industry STD TermSOIC
JEDEC CodeR-PDSO-G
Package QTY40
CarrierTUBE
Device MarkingUC2854DW
Width (mm)7.5
Length (mm)10.3
Thickness (mm)2.35
Pitch (mm)1.27
Max Height (mm)2.65
Mechanical DataHerunterladen

Parameter

Control MethodCCM
Device TypeSingle-phase PFC
Operating Supply Current10 mA
Operating Supply(Max)30 V
Operating Temperature Range-40 to 85 C
Package GroupSOIC
Package Size: mm2:W x L16SOIC: 106 mm2: 10.3 x 10.3(SOIC) PKG
Peak Output Sink Current Gate Drive1 A
Peak Output Source Current Gate Drive-1 A
Practical Operating Frequency(Max)0.2 MHz
RatingCatalog
Special FeaturesAverage Current Mode,Enable
Startup Current1.5 mA
UVLO Thresholds On/Off16/10 V

Öko-Plan

RoHSCompliant

Anwendungshinweise

  • U-134 UC3854 Controlled Power Factor Correction Circuit Design
    PDF, 346 Kb, Datei veröffentlicht: Sep 5, 1999
    The UC1854 provides active power factor correction for power systems that otherwise would draw non-sinusoidal current from sinusoidal power lines. This device implements all the control functions necessary to build a power supply capable of optimally using available power-line current while minimizing line-current distortion. This application note describes the concepts and design of a boost prere
  • DN-39E Optimizing Performance in UC3854 Power Factor Correction Applications
    PDF, 277 Kb, Datei veröffentlicht: Sep 5, 1999
    The performance of the UC3854 Power-Factor Correction IC in the 250W application example has been evaluated using a precision PFC/THD instrument. The result was a power factor of 0.999 and Total Harmonic Distortion (THD) of 3.81%, measured to the 50th line frequency harmonic at nominal line and full load. Users should get similar results at these conditions. as well as over most line and load rang
  • DN-41 Extend Current Transformer Range
    PDF, 37 Kb, Datei veröffentlicht: Sep 5, 1999
    The problems with self reset of current transformers for unipolar pulse applications can be overcome with simple forced-reset techniques derived from magnetic amplifiers. Duty factors above 90% are achievable with these techniques. This design note describes a circuit configured for forced reset and a configuration that generates a negative voltage from the current transformer.
  • AC Requirements for Power Factor Correction Circuits
    PDF, 29 Kb, Datei veröffentlicht: Mar 28, 2002
    This technical brief identifies the recommended range of IAC for each of the devices within the UCC3854 family of PFC controllers.
  • Accurate PWM Duty Cycle Clamp
    PDF, 58 Kb, Datei veröffentlicht: Jan 25, 2002
    Power supply applications using current sense transformers require a duty cycle clamp on the pulse width modulator (PWM) to ensure transformer reset. Not all PWMs come with a duty cycle clamp presenting a problem for the power supply designer. This application note shows how to implement a duty cycle clamp by using a simple delay circuit.

Modellreihe

Herstellerklassifikation

  • Semiconductors > Power Management > Offline and Isolated DC/DC Controllers and Converters > Power Factor Correction