Datasheet Texas Instruments ADS8555SPM — Datenblatt
Hersteller | Texas Instruments |
Serie | ADS8555 |
Artikelnummer | ADS8555SPM |
16-Bit-ADC 64-LQFP -40 bis 125 mit 6 Kanälen und gleichzeitiger Abtastung
Datenblätter
ADS8555 16-Bit, Six-Channel, Simultaneous Sampling Analog-to-Digital Converter datasheet
PDF, 1.2 Mb, Revision: D, Datei veröffentlicht: Feb 3, 2016
Auszug aus dem Dokument
Preise
Status
Lifecycle Status | Active (Recommended for new designs) |
Manufacture's Sample Availability | Yes |
Verpackung
Pin | 64 | 64 |
Package Type | PM | PM |
Industry STD Term | LQFP | LQFP |
JEDEC Code | S-PQFP-G | S-PQFP-G |
Package QTY | 160 | 160 |
Carrier | TUBE | TUBE |
Device Marking | 8555 | ADS |
Width (mm) | 10 | 10 |
Length (mm) | 10 | 10 |
Thickness (mm) | 1.4 | 1.4 |
Pitch (mm) | .5 | .5 |
Max Height (mm) | 1.6 | 1.6 |
Mechanical Data | Herunterladen | Herunterladen |
Parameter
# Input Channels | 6 |
Analog Voltage AVDD(Max) | 5.5 V |
Analog Voltage AVDD(Min) | 4.5 V |
Architecture | SAR |
Digital Supply(Max) | 5.5 V |
Digital Supply(Min) | 2.7 V |
INL(Max) | 3 +/-LSB |
Input Range(Max) | 12 V |
Input Range(Min) | -12 V |
Input Type | Single-Ended |
Integrated Features | Daisy-Chainable,Oscillator |
Interface | Parallel,SPI |
Multi-Channel Configuration | Simultaneous Sampling |
Operating Temperature Range | -40 to 125 C |
Package Group | LQFP |
Package Size: mm2:W x L | 64LQFP: 144 mm2: 12 x 12(LQFP) PKG |
Power Consumption(Typ) | 335 mW |
Rating | Catalog |
Reference Mode | Ext,Int |
Resolution | 16 Bits |
SINAD | 89.5 dB |
SNR | 91.5 dB |
Sample Rate (max) | 630kSPS SPS |
Sample Rate(Max) | 0.63 MSPS |
THD(Typ) | -94 dB |
Öko-Plan
RoHS | Compliant |
Anwendungshinweise
- Driver Circuit Design Considerations for ADS855xPDF, 1.3 Mb, Datei veröffentlicht: Aug 27, 2012
- Determining Minimum Acquisition Times for SAR ADCs, part 2PDF, 215 Kb, Datei veröffentlicht: Mar 17, 2011
The input structure circuit of a successive-approximation register analog-to-digital converter (SAR ADC) incombination with the driving circuit forms a transfer function that can be used to determine minimum acquisition times for different types of applied input signals. This application report, which builds on Determining Minimum Acquisition Times for SAR ADCs When a Step Function is Applied to
Modellreihe
Serie: ADS8555 (2)
- ADS8555SPM ADS8555SPMR
Herstellerklassifikation
- Semiconductors > Data Converters > Analog-to-Digital Converters (ADCs) > Precision ADCs (<=10MSPS)