Datasheet Texas Instruments UC1854J — Datenblatt
Hersteller | Texas Instruments |
Serie | UC1854 |
Artikelnummer | UC1854J |
High Power Factor Preregulator 16-CDIP -55 bis 125
Datenblätter
UCx854 High-Power Factor Preregulator datasheet
PDF, 949 Kb, Revision: A, Datei veröffentlicht: Dec 16, 2016
Auszug aus dem Dokument
Preise
Status
Lifecycle Status | Active (Recommended for new designs) |
Manufacture's Sample Availability | No |
Verpackung
Pin | 16 |
Package Type | J |
Industry STD Term | CDIP |
JEDEC Code | R-GDIP-T |
Package QTY | 1 |
Carrier | TUBE |
Device Marking | UC1854J |
Width (mm) | 6.92 |
Length (mm) | 19.56 |
Thickness (mm) | 4.57 |
Pitch (mm) | 2.54 |
Max Height (mm) | 5.08 |
Mechanical Data | Herunterladen |
Parameter
Control Method | CCM |
Duty Cycle(Max) | 95 % |
Operating Temperature Range | -55 to 125 C |
Package Group | CDIP |
Package Size: mm2:W x L | See datasheet (CDIP) PKG |
Rating | Military |
Special Features | Average Current Mode,Enable |
UVLO Thresholds On/Off | 16/10 V |
Öko-Plan
RoHS | See ti.com |
Anwendungshinweise
- U-134 UC3854 Controlled Power Factor Correction Circuit DesignPDF, 346 Kb, Datei veröffentlicht: Sep 5, 1999
The UC1854 provides active power factor correction for power systems that otherwise would draw non-sinusoidal current from sinusoidal power lines. This device implements all the control functions necessary to build a power supply capable of optimally using available power-line current while minimizing line-current distortion. This application note describes the concepts and design of a boost prere - DN-39E Optimizing Performance in UC3854 Power Factor Correction ApplicationsPDF, 277 Kb, Datei veröffentlicht: Sep 5, 1999
The performance of the UC3854 Power-Factor Correction IC in the 250W application example has been evaluated using a precision PFC/THD instrument. The result was a power factor of 0.999 and Total Harmonic Distortion (THD) of 3.81%, measured to the 50th line frequency harmonic at nominal line and full load. Users should get similar results at these conditions. as well as over most line and load rang - DN-41 Extend Current Transformer RangePDF, 37 Kb, Datei veröffentlicht: Sep 5, 1999
The problems with self reset of current transformers for unipolar pulse applications can be overcome with simple forced-reset techniques derived from magnetic amplifiers. Duty factors above 90% are achievable with these techniques. This design note describes a circuit configured for forced reset and a configuration that generates a negative voltage from the current transformer. - AC Requirements for Power Factor Correction CircuitsPDF, 29 Kb, Datei veröffentlicht: Mar 28, 2002
This technical brief identifies the recommended range of IAC for each of the devices within the UCC3854 family of PFC controllers. - Accurate PWM Duty Cycle ClampPDF, 58 Kb, Datei veröffentlicht: Jan 25, 2002
Power supply applications using current sense transformers require a duty cycle clamp on the pulse width modulator (PWM) to ensure transformer reset. Not all PWMs come with a duty cycle clamp presenting a problem for the power supply designer. This application note shows how to implement a duty cycle clamp by using a simple delay circuit.
Modellreihe
Serie: UC1854 (6)
Herstellerklassifikation
- Semiconductors > Space & High Reliability > Power Management Products > Offline and Isolated DC/DC Controller and Converter