Datasheet Texas Instruments SN65HVD23DRG4 — Datenblatt
Hersteller | Texas Instruments |
Serie | SN65HVD23 |
Artikelnummer | SN65HVD23DRG4 |
Erweiterter Gleichtakt-RS-485-Transceiver 8-SOIC -40 bis 85
Datenblätter
SN65HVD2x Extended Common-Mode RS-485 Transceivers datasheet
PDF, 1.3 Mb, Revision: F, Datei veröffentlicht: Nov 18, 2016
Auszug aus dem Dokument
Preise
Status
Lifecycle Status | Active (Recommended for new designs) |
Manufacture's Sample Availability | No |
Verpackung
Pin | 8 |
Package Type | D |
Industry STD Term | SOIC |
JEDEC Code | R-PDSO-G |
Package QTY | 2500 |
Carrier | LARGE T&R |
Device Marking | VP23 |
Width (mm) | 3.91 |
Length (mm) | 4.9 |
Thickness (mm) | 1.58 |
Pitch (mm) | 1.27 |
Max Height (mm) | 1.75 |
Mechanical Data | Herunterladen |
Parameter
Common Mode Range | -20 to 25 |
Duplex | Half |
Fail Safe | Open,Short |
Fault Protection | -27 to 27 V |
HBM ESD | 16 kV |
ICC(Max) | 11 mA |
IEC 61000-4-2 Contact | N/A +/- kV |
Isolated | No |
No. of RX | 1 |
No. of TX | 1 |
Number of Nodes | 64 |
Operating Temperature Range | -40 to 85 C |
Package Group | SOIC |
Rating | Catalog |
Signaling Rate(Max) | 25 Mbps |
Supply Voltage(s)(Nom) | 5 V |
Öko-Plan
RoHS | Compliant |
Design Kits und Evaluierungsmodule
- Evaluation Modules & Boards: SN65HVD22EVM
SN65HVD22EVM Evaluation Module
Lifecycle Status: Active (Recommended for new designs) - Evaluation Modules & Boards: RS485-HF-DPLX-EVM
RS-485 Half-Duplex Evaluation Module
Lifecycle Status: Active (Recommended for new designs)
Anwendungshinweise
- Use Receiver Equalization to Extend RS-485 Data Communications*PDF, 1.6 Mb, Datei veröffentlicht: Jul 6, 2004
System designers can use receiver equalization to extend their RS-485 data transmission applications in terms of longer cable distances or higher signaling rates. This application report discusses the benefits of using fixed receiver equalization for specific combinations of signaling rate, cable type, and node-to-node distance. Examples showing discrete implementations and integrated solutions ar - The RS-485 Unit Load and Maximum Number of Bus ConnectionsPDF, 197 Kb, Datei veröffentlicht: Mar 15, 2004
The TIA/EIA-485 (RS-485) standard defines a Unit Load and confines bus configurations to 32. This report explains the Unit-Load concept and how it relates to the maximum number of bus connections. Fractional Unit-Load devices, such at the 1/8th Unit-Load SN65HVD21 and SN65HVD06, allow up to 256 devices on a single bus segment.
Modellreihe
Serie: SN65HVD23 (5)
- SN65HVD23D SN65HVD23DG4 SN65HVD23DR SN65HVD23DRG4 SN65HVD23P
Herstellerklassifikation
- Semiconductors > Interface > RS-485/RS-422