Datasheet Texas Instruments OPA2691I-14DRG4 — Datenblatt

HerstellerTexas Instruments
SerieOPA2691
ArtikelnummerOPA2691I-14DRG4
Datasheet Texas Instruments OPA2691I-14DRG4

Dual-Breitband-Stromrückkopplungs-Operationsverstärker mit Deaktivierung von 14-SOIC -40 bis 85

Datenblätter

Dual Wideband, Current-Feedback Operational Amplifier With Disable datasheet
PDF, 1.1 Mb, Revision: D, Datei veröffentlicht: Jul 2, 2008
Auszug aus dem Dokument

Preise

Status

Lifecycle StatusActive (Recommended for new designs)
Manufacture's Sample AvailabilityNo

Verpackung

Pin14
Package TypeD
Industry STD TermSOIC
JEDEC CodeR-PDSO-G
Package QTY2500
CarrierLARGE T&R
Device MarkingOPA2691
Width (mm)3.91
Length (mm)8.65
Thickness (mm)1.58
Pitch (mm)1.27
Max Height (mm)1.75
Mechanical DataHerunterladen

Parameter

2nd Harmonic70 dBc
3rd Harmonic74 dBc
@ MHz5
Acl, min spec gain1 V/V
Additional FeaturesShutdown
ArchitectureBipolar,Current FB
BW @ Acl280 MHz
CMRR(Min)52 dB
CMRR(Typ)56 dB
GBW(Typ)280 MHz
Input Bias Current(Max)35000000 pA
Iq per channel(Max)5.3 mA
Iq per channel(Typ)5.1 mA
Number of Channels2
Offset Drift(Typ)20 uV/C
Operating Temperature Range-40 to 85 C
Output Current(Typ)190 mA
Package GroupSOIC
Package Size: mm2:W x L8SOIC: 29 mm2: 6 x 4.9(SOIC) PKG
Rail-to-RailNo
RatingCatalog
Slew Rate(Typ)2100 V/us
Total Supply Voltage(Max)12 +5V=5, +/-5V=10
Total Supply Voltage(Min)4 +5V=5, +/-5V=10
Vn at 1kHz(Typ)1.7 nV/rtHz
Vn at Flatband(Typ)1.7 nV/rtHz
Vos (Offset Voltage @ 25C)(Max)3 mV

Öko-Plan

RoHSCompliant

Design Kits und Evaluierungsmodule

  • Evaluation Modules & Boards: DEM-OPA-SO-2D
    DEM-OPA-SO-2D
    Lifecycle Status: Active (Recommended for new designs)
  • Evaluation Modules & Boards: DEM-OPA268XN
    DEM-OPA268xN: Demonstration Fixture
    Lifecycle Status: Active (Recommended for new designs)
  • Evaluation Modules & Boards: DEM-OPA268XU
    DEM-OPA268xU: Demonstration Fixture
    Lifecycle Status: Active (Recommended for new designs)
  • Evaluation Modules & Boards: DEM-OPA-SO-2A
    DEM-OPA-SO-2A
    Lifecycle Status: Active (Recommended for new designs)

Anwendungshinweise

  • Measuring Board Parasitics in High-Speed Analog Design
    PDF, 134 Kb, Datei veröffentlicht: Jul 7, 2003
    Successful circuit designs using high-speed amplifiers can depend upon understanding and identifying parasitic PCB components. Simulating a design while including PCB parasitics can protect against unpleasant production surprises. This application report discusses an easy method for measuring parasitic components in a prototype or final PC board design by using a standard oscilloscope and low freq
  • Tuning in Amplifiers
    PDF, 44 Kb, Datei veröffentlicht: Oct 2, 2000
    Have you ever had the experience of designing an analog gain block with an amplifier that is specified to be unity gain stable only to find that it is oscillating out of control in your circuit? Or have you ever replaced a stable voltage feedback amplifier with a current feedback amplifier to find that the current feedback amplifier immediately oscillates when placed in the amplifier socket? Oscil
  • Active filters using current-feedback amplifiers
    PDF, 227 Kb, Datei veröffentlicht: Feb 25, 2005
  • ADS5500, OPA695: PC Board Layout for Low Distortion High-Speed ADC Drivers
    PDF, 273 Kb, Datei veröffentlicht: Apr 22, 2004
    Once an analog-to-digital converter (ADC) and a driver/interface have been selected for a given application, the next step to achieving excellent performance is laying out the printed circuit board (PCB) that will support the application. This application report describes several techniques for optimizing a high-speed, 14-bit performance, differential driver PCB layout using a wideband operation
  • RLC Filter Design for ADC Interface Applications (Rev. A)
    PDF, 299 Kb, Revision: A, Datei veröffentlicht: May 13, 2015
    As high performance Analog-to-Digital Converters (ADCs) continue to improve in their performance, the last stage interface from the final amplifier into the converter inputs becomes a critical element in the system design if the full converter dynamic range is desired. This application note describes the performance and design equations for a simple passive 2nd-order filter used successfully in AD
  • Expanding the usability of current-feedback amplifiers
    PDF, 215 Kb, Datei veröffentlicht: Feb 28, 2005
  • Single-Supply Operation of Operational Amplifiers
    PDF, 77 Kb, Datei veröffentlicht: Oct 2, 2000
    Operation of op amps from single supply voltages is useful when negative supply voltages are not available. Furthermore, certain applications using high voltage and high current op amps can derive important benefits from single supply operation.
  • Current Feedback Amplifiers: Review, Stability Analysis, and Applications
    PDF, 53 Kb, Datei veröffentlicht: Nov 20, 2000
    The majority of op amp circuits are closed-loop feedback systems that implement classical control theory analysis. Analog designers are comfortable with Voltage FeedBack (VFB) op amps in a closed-loop system and are familiar with the ideal op amp approximations feedback permit. This application bulletin will demonstrate how CFB op amps can be analyzed in a similar fashion. Once the closed-loop sim
  • Noise Analysis for High Speed Op Amps (Rev. A)
    PDF, 256 Kb, Revision: A, Datei veröffentlicht: Jan 17, 2005
    As system bandwidths have increased an accurate estimate of the noise contribution for each element in the signal channel has become increasingly important. Many designers are not however particularly comfortable with the calculations required to predict the total noise for an op amp or in the conversions between the different descriptions of noise. Considerable inconsistency between manufactu
  • Wireline Data Transmission and Reception
    PDF, 191 Kb, Datei veröffentlicht: Jan 27, 2010
    Many types of wires are widely used to transmit data. Specifically, Category 3 and Category 5 (Cat3 and Cat5e, respectively)—also known as unshielded twisted pair or UTP lines—are now recommended for new telephone installations. Coaxial (coax) cables are used to distribute cable television (CATV) signals throughout a home. #12 and #14 American wire gauge (AWG) electric power distribution wire is a
  • Stabilizing Current-Feedback Op Amps While Optimizing Circuit Performance
    PDF, 280 Kb, Datei veröffentlicht: Apr 28, 2004
    Optimizing a circuit design with a current-feedback (CFB) op amp is a relatively straightforward task, once one understands how CFB op amps achieve stability. This application note explains a 2nd-order CFB model so that any designer can better understand the flexibility of the CFB op amp. This report also discusses stability analysis, the effects of parasitic components due to PCBs, optimization
  • Op Amp Performance Analysis
    PDF, 76 Kb, Datei veröffentlicht: Oct 2, 2000
    This bulletin reflects the analysis power gained through knowledge of an op amp circuit's feedback factor. Feedback dictates the performance of an op amp both in function and in quality. The major specifications of the amplifier descibe an open-loop device awaiting feedback direction of the end circuit's function. Just how well the amplifier performs the function reflects through the feedback inte

Modellreihe

Herstellerklassifikation

  • Semiconductors > Amplifiers > Operational Amplifiers (Op Amps) > High-Speed Op Amps (>=50MHz)

Andere Namen:

OPA2691I14DRG4, OPA2691I 14DRG4