Datasheet Texas Instruments OPA2341DGSA/250G4 — Datenblatt

HerstellerTexas Instruments
SerieOPA2341
ArtikelnummerOPA2341DGSA/250G4
Datasheet Texas Instruments OPA2341DGSA/250G4

Dual, RRIO, Single Supply, 5,5 MHz, Operationsverstärker mit Abschaltung 10-VSSOP -55 bis 125

Datenblätter

OPA341,OPA2341: Single-Supply, Rail-to-Rail Op-Amp with Shutdown MicroAmp Series datasheet
PDF, 779 Kb, Revision: A, Datei veröffentlicht: Jul 11, 2001
Auszug aus dem Dokument

Preise

Status

Lifecycle StatusActive (Recommended for new designs)
Manufacture's Sample AvailabilityNo

Verpackung

Pin10
Package TypeDGS
Industry STD TermVSSOP
JEDEC CodeS-PDSO-G
Package QTY250
CarrierSMALL T&R
Device MarkingC41
Width (mm)3
Length (mm)3
Thickness (mm)1.02
Pitch (mm).5
Max Height (mm)1.07
Mechanical DataHerunterladen

Parameter

Additional FeaturesShutdown
ArchitectureCMOS
CMRR(Min)76 dB
CMRR(Typ)90 dB
GBW(Typ)5.5 MHz
Input Bias Current(Max)10 pA
Iq per channel(Max)1 mA
Iq per channel(Typ)0.75 mA
Number of Channels2
Offset Drift(Typ)2 uV/C
Operating Temperature Range-55 to 125 C
Output Current(Typ)50 mA
Package GroupVSSOP
Package Size: mm2:W x L10VSSOP: 15 mm2: 4.9 x 3(VSSOP) PKG
Rail-to-RailIn,Out
RatingCatalog
Slew Rate(Typ)6 V/us
Total Supply Voltage(Max)5.5 +5V=5, +/-5V=10
Total Supply Voltage(Min)2.7 +5V=5, +/-5V=10
Vn at 1kHz(Typ)25 nV/rtHz
Vos (Offset Voltage @ 25C)(Max)5 mV

Öko-Plan

RoHSCompliant

Anwendungshinweise

  • Tuning in Amplifiers
    PDF, 44 Kb, Datei veröffentlicht: Oct 2, 2000
    Have you ever had the experience of designing an analog gain block with an amplifier that is specified to be unity gain stable only to find that it is oscillating out of control in your circuit? Or have you ever replaced a stable voltage feedback amplifier with a current feedback amplifier to find that the current feedback amplifier immediately oscillates when placed in the amplifier socket? Oscil
  • Single-Supply Operation of Operational Amplifiers
    PDF, 77 Kb, Datei veröffentlicht: Oct 2, 2000
    Operation of op amps from single supply voltages is useful when negative supply voltages are not available. Furthermore, certain applications using high voltage and high current op amps can derive important benefits from single supply operation.
  • Op Amp Performance Analysis
    PDF, 76 Kb, Datei veröffentlicht: Oct 2, 2000
    This bulletin reflects the analysis power gained through knowledge of an op amp circuit's feedback factor. Feedback dictates the performance of an op amp both in function and in quality. The major specifications of the amplifier descibe an open-loop device awaiting feedback direction of the end circuit's function. Just how well the amplifier performs the function reflects through the feedback inte

Modellreihe

Serie: OPA2341 (2)

Herstellerklassifikation

  • Semiconductors > Amplifiers > Operational Amplifiers (Op Amps) > Precision Op Amps