Datasheet Texas Instruments OPA211SKGD1 — Datenblatt

HerstellerTexas Instruments
SerieOPA211-HT
ArtikelnummerOPA211SKGD1
Datasheet Texas Instruments OPA211SKGD1

Hochtemperatur 1,1 nV / rtHz Rauschen, geringer Stromverbrauch, präziser Operationsverstärker 0-XCEPT -55 bis 210

Datenblätter

1.1 nV/Hz Noise, Low Power, Precision Operational Amplifier datasheet
PDF, 468 Kb, Revision: D, Datei veröffentlicht: Oct 3, 2013
Auszug aus dem Dokument

Preise

Status

Lifecycle StatusActive (Recommended for new designs)
Manufacture's Sample AvailabilityNo

Verpackung

Package TypeKGD
Package QTY400

Parameter

Additional FeaturesShutdown
ArchitectureBipolar
CMRR(Min)110 dB
CMRR(Typ)120 dB
GBW(Typ)45 MHz
IIB(Max)250000 pA
Iq per channel(Max)7.5 mA
Iq per channel(Typ)3.6 mA
Number of Channels1
Offset Drift(Typ)2 uV/C
Operating Temperature Range-55 to 210 C
Output Current(Typ)30 mA
Package GroupCFP
Package Size: mm2:W x LSee datasheet (CFP) PKG
Rail-to-RailOut
RatingCatalog
Slew Rate(Typ)27 V/us
Total Supply Voltage(Max)36 +5V=5, +/-5V=10
Total Supply Voltage(Min)4.5 +5V=5, +/-5V=10
Vn at 1kHz(Typ)1.1 nV/rtHz
Vos (Offset Voltage @ 25C)(Max)0.26 mV

Öko-Plan

RoHSSee ti.com

Design Kits und Evaluierungsmodule

  • Evaluation Modules & Boards: HEATEVM
    Harsh Environment Acquisition Terminal (H.E.A.T) Evaluation Module Platform for High-Temperature App
    Lifecycle Status: Obsolete (Manufacturer has discontinued the production of the device)

Anwendungshinweise

  • Tuning in Amplifiers
    PDF, 44 Kb, Datei veröffentlicht: Oct 2, 2000
    Have you ever had the experience of designing an analog gain block with an amplifier that is specified to be unity gain stable only to find that it is oscillating out of control in your circuit? Or have you ever replaced a stable voltage feedback amplifier with a current feedback amplifier to find that the current feedback amplifier immediately oscillates when placed in the amplifier socket? Oscil
  • Single-Supply Operation of Operational Amplifiers
    PDF, 77 Kb, Datei veröffentlicht: Oct 2, 2000
    Operation of op amps from single supply voltages is useful when negative supply voltages are not available. Furthermore, certain applications using high voltage and high current op amps can derive important benefits from single supply operation.
  • Op Amp Performance Analysis
    PDF, 76 Kb, Datei veröffentlicht: Oct 2, 2000
    This bulletin reflects the analysis power gained through knowledge of an op amp circuit's feedback factor. Feedback dictates the performance of an op amp both in function and in quality. The major specifications of the amplifier descibe an open-loop device awaiting feedback direction of the end circuit's function. Just how well the amplifier performs the function reflects through the feedback inte

Modellreihe

Serie: OPA211-HT (3)

Herstellerklassifikation

  • Semiconductors > Space & High Reliability > Amplifier > Operational Amplifiers