Datasheet Texas Instruments OPA121KP — Datenblatt

HerstellerTexas Instruments
SerieOPA121
ArtikelnummerOPA121KP
Datasheet Texas Instruments OPA121KP

Kostengünstiger Präzisions-Difet-Operationsverstärker 8-PDIP

Datenblätter

Low Cost Precision Difet® Operational Amplifier datasheet
PDF, 500 Kb, Datei veröffentlicht: Sep 27, 2000
Auszug aus dem Dokument

Preise

Status

Lifecycle StatusObsolete (Manufacturer has discontinued the production of the device)
Manufacture's Sample AvailabilityNo

Verpackung

Pin8
Package TypeP
Industry STD TermPDIP
JEDEC CodeR-PDIP-T
Width (mm)6.35
Length (mm)9.81
Thickness (mm)3.9
Pitch (mm)2.54
Max Height (mm)5.08
Mechanical DataHerunterladen

Ersatz

ReplacementOPA121KU
Replacement CodeF

Parameter

Additional FeaturesVos Adj Pin
Approx. Price (US$)6.16 | 1ku
ArchitectureFET
CMRR(Min)(dB)82
CMRR(Typ)(dB)100
GBW(Typ)(MHz)2
Input Bias Current(Max)(pA)5
Iq per channel(Max)(mA)4
Iq per channel(Typ)(mA)2.5
Number of Channels(#)1
Offset Drift(Typ)(uV/C)3
Operating Temperature Range(C)0 to 70
Output Current(Typ)(mA)40
Package GroupSOIC
Package Size: mm2:W x L (PKG)See datasheet (PDIP)
Rail-to-RailNo
RatingCatalog
Slew Rate(Typ)(V/us)2
Total Supply Voltage(Max)(+5V=5, +/-5V=10)36
Total Supply Voltage(Min)(+5V=5, +/-5V=10)10
Vn at 1kHz(Typ)(nV/rtHz)8
Vos (Offset Voltage @ 25C)(Max)(mV)2

Öko-Plan

RoHSNot Compliant
Pb FreeNo

Anwendungshinweise

  • Diode-Connected FET Protects Op Amps
    PDF, 49 Kb, Datei veröffentlicht: Oct 2, 2000
    Providing input-overload protection for sensitive measurement circuits proves difficult when you must not degrade the circuits? performance in the process. It?s an especially tricky problem when you?re measuring a material?s dielectric properties. In such an application, an ultra-low input bias current op amp serves as a current integrator to measure a dielectric?s response to a 100V step.
  • Compensate Transimpedance Amplifiers Intuitively (Rev. A)
    PDF, 69 Kb, Revision: A, Datei veröffentlicht: Mar 30, 2005
    Transimpedance amplifiers are used to convert low-level photodiode currents to usable voltage signals. All too often, the amplifiers have to be empirically compensated to operate properly. The problem can be easily understood if one looks at all the elements involved.
  • Tuning in Amplifiers
    PDF, 44 Kb, Datei veröffentlicht: Oct 2, 2000
    Have you ever had the experience of designing an analog gain block with an amplifier that is specified to be unity gain stable only to find that it is oscillating out of control in your circuit? Or have you ever replaced a stable voltage feedback amplifier with a current feedback amplifier to find that the current feedback amplifier immediately oscillates when placed in the amplifier socket? Oscil
  • Single-Supply Operation of Operational Amplifiers
    PDF, 77 Kb, Datei veröffentlicht: Oct 2, 2000
    Operation of op amps from single supply voltages is useful when negative supply voltages are not available. Furthermore, certain applications using high voltage and high current op amps can derive important benefits from single supply operation.
  • Op Amp Performance Analysis
    PDF, 76 Kb, Datei veröffentlicht: Oct 2, 2000
    This bulletin reflects the analysis power gained through knowledge of an op amp circuit's feedback factor. Feedback dictates the performance of an op amp both in function and in quality. The major specifications of the amplifier descibe an open-loop device awaiting feedback direction of the end circuit's function. Just how well the amplifier performs the function reflects through the feedback inte

Modellreihe

Herstellerklassifikation

  • Semiconductors > Amplifiers > Operational Amplifiers (Op Amps) > Precision Op Amps