PDF, 150 Kb, Datei hochgeladen: Jul 31, 2016, Seiten: 6
JFET VHF/UHF Amplifiers
Auszug aus dem Dokument
2N5486
JFET VHF/UHF Amplifiers
N−Channel — Depletion
Features • Pb−Free Packages are Available* http://onsemi.com
1 DRAIN MAXIMUM RATINGS (TJ = 25°C unless otherwise noted)
Rating Symbol Value Unit Drain −Gate Voltage VDG 25 Vdc Reverse Gate −Source Voltage VGSR 25 Vdc ID 30 mAdc Forward Gate Current IG(f) 10 mAdc Total Device Dissipation @ TC = 25°C
Derate above 25°C PD 350
2.8 mW
mW/°C TJ, Tstg −65 to +150 °C Drain Current Operating and Storage Junction
Temperature Range 3
GATE 2 SOURCE Stresses exceeding Maximum Ratings may damage the device. Maximum
Ratings are stress ratings only. Functional operation above the Recommended
Operating Conditions is not implied. Extended exposure to stresses above the
Recommended Operating Conditions may affect device reliability. TO−92 (TO−226AA)
CASE 29−11
STYLE 5 MARKING DIAGRAM 2N
5486
AYWWG
G 2N5486 = Device Code
A
= Assembly Location
Y
= Year
…