Datasheet Texas Instruments LM35DZ/NOPB — Datenblatt

HerstellerTexas Instruments
SerieLM35
ArtikelnummerLM35DZ/NOPB
Datasheet Texas Instruments LM35DZ/NOPB

± 0,5 ° C Temperatursensor mit Analogausgang mit 30 V Kapazität 3-TO-92 0 bis 100

Datenblätter

Datasheet LM35
PDF, 1.7 Mb, Revision: G, Datei veröffentlicht: Aug 15, 2016, Seiten: 36
Precision Centigrade Temperature Sensors
Auszug aus dem Dokument

Preise

Status

Lifecycle StatusActive (Recommended for new designs)
Manufacture's Sample AvailabilityYes

Verpackung

Pin33
Package TypeLPLP
Industry STD TermTO-92TO-92
JEDEC CodeO-PBCY-WO-PBCY-W
Package QTY18001800
Device MarkingLM35DZ
Width (mm)4.34.3
Length (mm)4.34.3
Thickness (mm)3.63.6
Pitch (mm)1.271.27
Max Height (mm)5.345.34
Mechanical DataHerunterladenHerunterladen

Parameter

InterfaceAnalog Output
Local Sensor Accuracy(Max)0.5 +/- C
Operating Temperature Range-40 to 110,-55 to 150,0 to 100,0 to 70 C
Package GroupTO-92
Package Size: mm2:W x L3TO-92: 18 mm2: 4.3 x 4.3(TO-92) PKG
RatingCatalog
Supply Current(Max)114 uA
Supply Voltage(Max)30 V
Supply Voltage(Min)4 V

Öko-Plan

RoHSCompliant

Anwendungshinweise

  • High-Efficiency 3A Battery Chargers Use LM2576 Regulators (Rev. B)
    PDF, 187 Kb, Revision: B, Datei veröffentlicht: Apr 23, 2013
    This application report describes two LM2576-based designs that provide up to 3A of current for batterycharging.
  • AN-460 LM34/LM35 Precision Monolithic Temperature Sensors (Rev. C)
    PDF, 495 Kb, Revision: C, Datei veröffentlicht: May 1, 2013
    This application report discusses the details and uses of the Texas Instruments LM34 and LM35 asprecision temperature sensors.
  • Thermocouple, Cold-Junction Compensation—Analog Approach
    PDF, 614 Kb, Datei veröffentlicht: Aug 27, 2014
    Temperature is the most commonly measured physical parameter in a variety of systems, including automotive, industrial, and consumer domains. There are various temperature transducers available to address the need of accurate temperature measurement. Thermocouples are widely popular because they are inexpensive, have a wide range, are small in size, and do not need excitation. This application not
  • TO-92 Packing Options / Ordering Instructions (Rev. A)
    PDF, 287 Kb, Revision: A, Datei veröffentlicht: Jun 23, 2010
  • AN-1852 Designing With pH Electrodes (Rev. A)
    PDF, 115 Kb, Revision: A, Datei veröffentlicht: May 1, 2013
    A pH electrode measures hydrogen ion (H+) activity and produces an electrical potential or voltage. Theoperation of the pH electrode is based on the principle that an electric potential develops when two liquidsof different pH come into contact at opposite sides of a thin glass membrane. This was originallydiscovered in 1906 by Max Cremer [1]. His discovery laid the foundation for Fritz Habe
  • Sensing and Monitoring for Control and Protection Seminar
    PDF, 245 Kb, Datei veröffentlicht: Feb 17, 2003
  • AN-480 A 40 MHz Programmable Video Op Amp
    PDF, 218 Kb, Datei veröffentlicht: May 11, 2004

Modellreihe

Herstellerklassifikation

  • Semiconductors > Space & High Reliability > Sensors > Temperature Sensor