Datasheet Texas Instruments LM358PE4 — Datenblatt

HerstellerTexas Instruments
SerieLM358
ArtikelnummerLM358PE4
Datasheet Texas Instruments LM358PE4

Duale Operationsverstärker 8-PDIP 0 bis 70

Datenblätter

Datasheet LM158, LM158A, LM258, LM258A, LM358, LM358A, LM2904, LM2904V
PDF, 2.0 Mb, Revision: U, Datei veröffentlicht: Jan 7, 2017, Seiten: 43
Dual Operational Amplifiers
Auszug aus dem Dokument

Preise

Status

Lifecycle StatusActive (Recommended for new designs)
Manufacture's Sample AvailabilityNo

Verpackung

Pin8
Package TypeP
Industry STD TermPDIP
JEDEC CodeR-PDIP-T
Package QTY50
CarrierTUBE
Width (mm)6.35
Length (mm)9.81
Thickness (mm)3.9
Pitch (mm)2.54
Max Height (mm)5.08
Mechanical DataHerunterladen

Parameter

ArchitectureBipolar
CMRR(Min)65 dB
CMRR(Typ)80 dB
FeaturesCost Optimized
GBW(Typ)0.7 MHz
Input Bias Current(Max)150000 pA
Iq per channel(Max)0.6 mA
Iq per channel(Typ)0.35 mA
Number of Channels2
Offset Drift(Typ)7 uV/C
Operating Temperature Range0 to 70 C
Output Current(Typ)30 mA
Package GroupPDIP
Package Size: mm2:W x LSee datasheet (PDIP) PKG
Rail-to-RailIn to V-
RatingCatalog
Slew Rate(Typ)0.3 V/us
Total Supply Voltage(Max)32 +5V=5, +/-5V=10
Total Supply Voltage(Min)3 +5V=5, +/-5V=10
Vn at 1kHz(Typ)40 nV/rtHz
Vos (Offset Voltage @ 25C)(Max)7 mV

Öko-Plan

RoHSCompliant
Pb FreeYes

Design Kits und Evaluierungsmodule

  • Evaluation Modules & Boards: DUAL-DIYAMP-EVM
    Dual Channel Universal Do-It-Yourself (DIY) Amplifier Circuit Evaluation Module
    Lifecycle Status: Active (Recommended for new designs)

Anwendungshinweise

  • AN-116 Use the LM158/LM258/LM358 Dual Single Supply Op Amp (Rev. B)
    PDF, 313 Kb, Revision: B, Datei veröffentlicht: Apr 23, 2013
    This application note discusses the use of the LM158/LM258/LM358 dual op amp when operated from asingle supply.
  • AN-30 Log Converters (Rev. B)
    PDF, 370 Kb, Revision: B, Datei veröffentlicht: May 1, 2013
    One of the most predictable non-linear elements commonly available is the bipolar transistor. Therelationship between collector current and emitter base voltage is precisely logarithmic from currentsbelow one picoamp to currents above one milliamp. Using a matched pair of transistors and integratedcircuit operational amplifiers it is relatively easy to construct a linear to logarithmic conv
  • AN-278 Designing with a New Super Fast Dual Norton Amplifier (Rev. B)
    PDF, 867 Kb, Revision: B, Datei veröffentlicht: Apr 23, 2013
    This application note provides new design ideas and discusses the positive impact of designing with theDual Norton amplifier.
  • AN-79 IC Preamplifier Challenges Choppers on Drift (Rev. B)
    PDF, 940 Kb, Revision: B, Datei veröffentlicht: May 1, 2013
    Since the introduction of monolithic IC amplifiers there has been a continual improvement in DC accuracy.Bias currents have been decreased by 5 orders of magnitude over the past 5 years. Low offset voltagedrift is also necessary in a high accuracy circuits. This is evidenced by the popularity of low drift amplifiertypes as well as the requests for selected low-drift op amps. However until n
  • Audio Applications of Linear Integrated Circuits
    PDF, 272 Kb, Datei veröffentlicht: May 2, 2004
  • AN-262 Applying Dual and Quad FET Op Amps (Rev. B)
    PDF, 1.1 Mb, Revision: B, Datei veröffentlicht: May 6, 2013
    The availability of dual and quad packaged FET op amps offers the designer all the traditional capabilitiesof FET op amps including low bias current and speed and some additional advantages. The cost-peramplifieris lower because of reduced package costs. This means that more amplifiers are available toimplement a function at a given cost making design easier. At the same time the availab
  • AN-263 Sine Wave Generation Techniques (Rev. C)
    PDF, 747 Kb, Revision: C, Datei veröffentlicht: Apr 22, 2013
    This application note describes the sine wave generation techniques to control frequency amplitude anddistortion levels.
  • AN-256 Circuitry for Inexpensive Relative Humidity Measurement (Rev. B)
    PDF, 262 Kb, Revision: B, Datei veröffentlicht: May 6, 2013
    Of all common environmental parameters humidity is perhaps the least understood and most difficult tomeasure. The most common electronic humidity detection methods albeit highly accurate are not obviousand tend to be expensive and complex (See Box). Accurate humidity measurement is vital to a number ofdiverse areas including food processing paper and lumber production pollution monitor
  • Get More Power Out of Dual or Quad Op-Amps
    PDF, 91 Kb, Datei veröffentlicht: Oct 2, 2002

Modellreihe

Herstellerklassifikation

  • Semiconductors > Amplifiers > Operational Amplifiers (Op Amps) > General-Purpose Op Amps